Technical Parameters of Interface
item
|
Min Value
|
Rated Value
|
Max Value
|
remarks
|
|
AC output
|
|||||
output power
|
700W |
|
|||
Peak power
|
1400W |
|
|||
overload capability
|
105%<load<114%@2min 114%<load<150%@1s 150%<load@0.5s |
report OVERLOAD, AC off; press the button to recover |
|||
BALDR 700WB500-S0-JP |
Output voltage
|
100V |
110V |
120V |
Interface Qty.: 4 |
Output current
|
7A |
6.36A |
5.83A |
|
|
output frequency
|
50/60Hz |
60Hz by default, support setting via screen |
|||
BALDR 700WB500-S0-EU |
Output voltage
|
220V |
230V |
240V |
Interface Qty.: 2 |
Output current
|
|
8.7A |
|
|
|
output frequency
|
50Hz |
|
|||
Inversion efficiency
|
|
90% |
|
|
|
Current crest ratio
|
|
3:1 |
|
|
|
Output voltage harmonic wave
|
|
|
5% |
|
|
Output short circuit protection
|
Available |
|
|||
Overtemperature protection threshold
|
85 ℃ |
90 ℃ |
95 ℃ |
Internal device temperature, 2s, turn off AC, |
|
DC out
|
|||||
Note: Total current is 30A; some loads will be turned off automatically when total current is over 30A |
|||||
Cigarette lighter |
Output voltage
|
12V |
13V |
14V |
Interface Qty.: 1 |
Output current
|
9A |
10A |
11A |
Cigarette lighter is in parallel connection with Interface 5521, total current is 10A |
|
overload power
|
|
150W |
|
2S |
|
Short-circuit protection
|
Available |
|
|||
5521 |
Output voltage
|
12V |
13V |
14V |
Interface Qty.: 2 |
Output current
|
9A |
10A |
11A |
2 interfaces are in parallel connection with cigarette lighter, total current is 10A |
|
overload power
|
|
|
150W |
2S |
|
Short-circuit protection
|
Available |
USB A×4
|
Output voltage
|
4.90V |
5.15V |
5.3V |
Interface Qty.: 4 |
Output current
|
2.9A |
3.0A |
3.8A |
Two-way total power: 30W |
|
Short-circuit protection
|
Available |
Auto recovery |
|||
Type-C
|
Interface type
|
Compatible with PD3.0(Max.100W) |
|||
Output parameters
|
5V-15V/3A,20VDC/5A |
|
|||
Short-circuit protection
|
Available |
|
|||
Wireless charging
|
default
|
Compatible with QI |
Interface Qty.: 1 |
||
output power
|
15W |
|
|||
LEDs
|
Luminous intensity
|
500LM |
Lighting sequence: Half bright, fully bright, SOS signal, LED lamp is off. |
||
DC input
|
|||||
Input power
|
|
|
200W |
AMASS socket |
|
Input voltage
|
12VDC |
|
28VDC |
||
Input current
|
|
|
10ADC |
||
Working mode
|
MPPT |
||||
Charger (T90)
|
|||||
Output interface
|
7909 socket |
200W charger (optional) |
|||
Max. output voltage
|
|
27.5VDC |
|
||
Max. output power
|
|
90W |
|
||
Display interface
|
|||||
LCD color screen
|
LCD
|
|
|||
Display function
|
(1) Display the battery capacity, input power, output power, AC frequency, overtemperature, overload and short circuit status; (2) The user can adjust the AC output frequency as 50Hz or 60Hz according to the specification; switch between ECO and non-ECO working mode. |
Note:
1. PV charging supports auto activation: If PV is connected to the equipment, the equipment charging will be activated automatically when solar energy is received. This function can be disabled by unplugging the PV charger upon full charging.
2. Support charging and discharging simultaneously. UPS is not supported.
Built-in Battery:
Item
|
Min. Value
|
Rated Value
|
Max. Value
|
Remarks
|
Battery type
|
LiFePO4 |
|
||
Cell capability
|
24Ah |
|
||
Series-parallel connection mode
|
7S4P |
|
||
Battery capacity
|
537Wh |
|
||
Battery voltage
|
21V |
22.4V |
25.2V |
Overall working voltage |
Single battery overvoltage protection
|
|
|
3.65V |
BMS protection point |
Single battery undervoltage protection
|
2.5V |
|
|
BMS protection point |
Short circuit protection
|
Available |
|
||
Discharge overtemperature protection
|
61℃ |
65℃ |
69℃ |
|
Discharge overtemperature recovery
|
51℃ |
55℃ |
59℃ |
|
Charge overtemperature protection
|
46℃ |
50℃ |
54℃ |
|
Charge overtemperature recovery
|
41℃ |
45℃ |
49℃ |
|
Charge low temperature protection
|
-4℃ |
0℃ |
-4℃ |
|
Recover charge lower temperature protection
|
1℃ |
5℃ |
9℃ |
|
Overall Parameters:
Item
|
Min. Value
|
Rated Value
|
Max. Value
|
Remarks
|
|
Noise
|
|
|
55dB |
|
|
Working ambient temperature
|
Charging
|
0℃ |
|
40℃ |
|
Discharging
|
-20℃ |
|
40℃ |
|
|
Storage ambient temperature
|
-10℃ |
|
45℃ |
|
|
Working altitude
|
|
|
2000m |
|
|
Dimensions (L×W×H)
|
275x 200x 203mm |
|
|||
Net weight
|
|
7.2KG |
|
Fan Start Condition:
Start Condition |
Remarks |
1. Start: AC temperature >60°C Stop: AC temperature <50°C, stop after 10s |
Be subject to actual temperature rise test when structure is completed |
2. Start: DC12V temperature >60°C Stop: DC12V temperature <50W, stop after 10s |
|
3. Start: Charging temperature >60°C Stop: Charging temperature <50°C, stop after 10s |
|
4. Start: Inversion power >500W Stop: Inversion power <400W, stop after 10s |
Button Operation:
Single button
|
1. Short press any button for about 1s to turn on or off corresponding functions 2. Long press any button for about 2s to turn off all functions |
Combined button
|
Setting of ECO mode and AC 50/60Hz frequency switch: Steps of setting: 1. When screen is on and AC is turned off, long press AC and USB button at the same time for about 2s to enter mode setting interface; 2. Frequency switch: The 50Hz/60Hz at the lower right corner of screen is current output frequency; short press AC button to change the output frequency; 3. ECO mode: The ECO character displayed at the upper left corner of screen means ECO mode is entered; 4. Press AC and USB button at the same time to quit setting mode and save settings. |
Introduction to LCD Screen:
Display contents:
|
1. iutput: A. The battery has 5 grids in total. When 0<Current electric quantity ≤20%, the 1st to the 5th grid will be on in turns, then become off and become on again. When 20<Current electric quantity ≤40%, the 1st grid will be normally on, the 2nd to the 5th grid will be on in turns, then become off and become on again in turns. The rest can be analogized in the same way. When electric quantity reaches 100%, all of five grids are normally on and maintained (different from output) B: INPUT shows the current input power; 3 bits are displayed by default. |
2. Output: A: Battery icon: The battery has 5 grids in total. When <Current electric quantity ≤20%, the 1st grid will be normally on, while the 2nd to the 5th grid will be off. When 20%<Current electric quantity ≤40%, the 1st and 2nd grid will be normally on, while the 3rd to the 5th grid will be on. The rest can be analogized in the same way. When 80%<Electric quantity≤100%, all of 5 grids will be normally on. (Pay attention to the difference with input). B: OUTPUT shows current output power; 3 bits are displayed by default. |
3. Alarm information Red characters are alarm information. It will be displayed only if alarm is triggered. |
4: Turn off screen A. Turn off screen within 2S when all outputs are closed; B: Turn off screen within 30S in standby status; C: Turn off screen without shutting down machine when error is reported |
5. ECO mode (default mode): When AC load is less than 10W for 4h successively, AC will be turned off to reduce loss of battery cell. When DC load is less than 1W for 4h successively, DC will be turned off. |
Fault Information:
Fault Code
|
Fault Information
|
Fault Introduction
|
Troubleshooting
|
|
Battery voltage alarm |
Electric quantity is ≤15% |
Charging |
TEMP
|
Temperature error |
Refer to Appendix 1 |
|
OVERLOAD
|
Output overload |
AC overload: 105%<load<120%@2Min 120%<load<150%@2s 150%<load@0.5s |
Reduce load, and press the button for recovery |
SHORT
|
Output short circuit |
1. AC output short circuit, turn off AC; 2. DC12V output short circuit, turn off DC; |