Technical Parameters:
Item
|
Nominal Value
|
Remarks
|
||||
AC Output |
||||||
Output power |
2000W |
2100W |
Display accuracy ±30W |
|||
Voltage grade |
100Vac |
110Vac/120Vac/230Vac |
AC output voltage |
|||
Overload capability |
2,000W |
2,000W<load<2,500W,2min; 2,500W<load,8~10S; |
LCD will report overload alarm after overload; disconnect AC output automatically when alarm lasts for 2min continuously; then remove load and restart AC. |
|||
2,100W |
2,100W<load<2,625W,2min; 2,625W<load<2,863W,8~10s; |
|||||
BALDR 2000WB2000-S0-JP |
Output voltage |
100V |
110V |
120V |
No-load voltage error ±2V, output *6 |
|
Output current |
20A |
19.1A |
17.5A |
/ |
||
Output frequency |
50/60Hz±0.5Hz |
60Hz by default, support setting via screen |
||||
BALDR 2000WB2000-S0-US |
Output voltage |
120V |
No-load voltage error ±2V, output *6 |
|||
Output current |
17.5A |
/ |
||||
Output frequency |
50/60Hz±0.5Hz |
60Hz by default, support setting via screen |
||||
BALDR 2000WB2000-S0-EU |
Output voltage |
230V |
No-load voltage error ±2V, output *4 |
|||
Output current |
9.1A |
/ |
||||
Output frequency |
50/60Hz±0.5Hz |
50Hz by default, support setting via screen |
||||
Max. inversion efficiency |
>88% |
AC max. efficiency (>70% load) max. efficiency |
||||
Current crest ratio |
2:1 |
Max. value |
||||
Output voltage harmonic wave |
3% |
Under nominal voltage |
||||
Output short circuit protection |
Available |
|
||||
Overtemperature protection threshold |
80℃±2 |
Internal cooler temperature, recovery value: 75℃±2 |
DC Output |
|||
Note: Total current of all DC is 30A; other DC output will be closed when total current is out of limit |
|||
Cigarette lighter*1 |
Output voltage |
13.5V(±1V) |
Interface Qty.: 1 |
Output current |
10A |
Cigarette lighter has parallel connection with Port 5521, total current is 10A. |
|
Overload power |
PLoad≥145W@2s |
Overload output protection PLoad<60W, Error±6W |
|
Short circuit protection |
Available |
Restart DC after short circuit is removed. |
|
5521*2 |
Output voltage |
13.5V(±1V) |
Interface Qty.: 2 |
Output current |
10A |
Cigarette lighter has parallel connection with two interfaces, total current is 10A. |
|
Overload power |
PLoad≥145W@2s |
Overload output protection. PLoad<60W Error±6W, Load≧60W error |
|
Short circuit protection |
Available |
Restart DC after short circuit is removed |
|
RV*1 |
Output voltage |
13.5V(±1V) |
Interface Qty.: 1 |
Output current |
30A |
Max. total current of DC output is 30A |
|
Overload power |
PLoad≥405W@2s |
PLoad<200W, Error±6W Pload≧200W Error±10W |
|
Short circuit protection |
Available |
Restart after short circuit is removed |
|
USB-A×2 (common) |
Output voltage |
5V(±0.25V) |
|
Output current |
3.0A |
Max. output of single port is 3A; max. output of 2 parallel ports is 3A, error ± |
|
Short circuit protection |
Available |
Auto recovery after load is removed |
|
USB-A (QC3.0) |
Output voltage |
5V×2 |
|
Output current |
2A\1A |
|
|
Short circuit protection |
Available |
Auto recovery after fault is removed |
Type-C |
Interface type |
Support PD3.0(100WMax) |
|
Output parameter |
5V/3A,9V/3A,12V/3A,15V/3A,20V/5A |
|
|
Short circuit protection |
Available |
Auto recovery after fault is removed |
|
Wireless charging |
QI1.2.4 standard |
Apple/ MI/Samsung SAMSUNG/LG/ Huawei, etc. |
Interface Qty.: 2 |
Output power |
5W/7.5W/10W/15W |
|
DC Input (PV or T500) |
||
Input power |
900W |
1. Power may not be displayed when charging power is less than 10W; it will show error is within 15W when charging power is high; 2. It will trigger protection when voltage is over 145V (±1V); recover automatically when voltage is reduced to 140V(±1V) 3. Trigger protection when current is over 15A (±1A); recover charging when fault is removed. |
Input voltage |
10Vdc-145Vdc |
|
Input current |
15A |
|
Work mode |
MPPT |
|
AC Charger (T500) |
||
Input port |
100Vac~240Vac |
|
Max. charging voltage |
58.4VDC |
|
Max charging power |
500W |
MAX |
Display Interface |
||
LCD color screen |
4.3’’ touch screen |
With touch screen function |
Screen function |
(1) Show voltage, power, charge/discharge status in real time; (2) User can adjust output voltage, frequency, charge mode, power consumption mode and time information in setting column; (3) User can check fault information, historical fault information, software/hardware version number. |
|
Bluetooth
|
||
Wireless upgrade
|
/ |
/ |
Wireless monitoring
|
/ |
/ |
Note:
1. PV charging supports auto activation: If PV is connected to the equipment, equipment charging will be activated automatically when solar energy is received. This function can be disabled by unplugging the PV charger upon full charging.
2. Support charging and discharging simultaneously. UPS is not supported.
Battery Parameters:
Item
|
Nominal Value |
Remarks |
Battery type |
LiFeO4 |
|
Cell capacity |
6000mAh |
|
Battery capacity |
2150Wh |
|
Battery voltage |
51.2V |
|
Single battery overvoltage protection |
3.65V |
|
Single battery undervoltage protection |
2.50V |
|
Short circuit protection |
Available |
|
Discharge overtemperature protection |
65℃ |
|
Discharge overtemperature recovery |
55℃ |
|
Charge overtemperature protection |
55℃ |
|
Charge overtemperature recovery |
55℃ |
|
Charge low temperature protection |
0℃ |
|
Recover charge lower temperature protection |
5℃ |
|
Overall Parameters:
Item
|
Nominal Value
|
Remarks
|
|
Noise |
≤53db |
Noise is related to air outlet of rear cover; it is 53dB temporarily and subject to further test. |
|
Working ambient temperature |
Charging |
0~40℃ |
|
Discharging |
-20~40℃ |
|
|
Storage ambient temperature |
-20~45℃ |
|
|
Working altitude |
<2,000m |
|
|
Dimensions (L×W×H) |
440*296*387.5mm |
|
|
Net weight |
30Kg |
|
Fault Code:
Fault Code |
Fault Information |
001 |
PV high voltage |
002 |
PV low voltage |
003 |
PV high current |
004 |
DC output short circuit |
005 |
Adapter high voltage |
006 |
Adapter low voltage |
|
007 |
Adapter relay error |
|
008 |
Adapter high current |
|
009 |
DC output branch current 1 is high |
|
010 |
DC output branch current 2 is high |
|
011 |
DC output branch current 3 is high |
|
012 |
DC output branch current 4 is high |
|
013 |
DC13 high voltage |
|
014 |
DC output soft start failure |
|
015 |
DC output relay failure |
|
016 |
BUS soft start failure |
|
017 |
INV soft start failure |
|
018 |
BUS low voltage |
|
019 |
BUS high voltage |
|
020 |
Inverter low voltage |
|
021 |
Inverter high voltage |
|
022 |
Inverter low frequency |
|
023 |
Inverter high frequency |
|
024 |
Inverter overcurrent |
|
025 |
Battery high voltage |
|
026 |
Battery low voltage |
|
027 |
Battery disconnected |
|
028 |
Fan fault |
|
029 |
NTC fault |
|
030 |
Sampling zero point check failure |
|
031 |
Inverter overload |
|
032 |
Inverter output short circuit |
|
033 |
SPI communication disconnection |
|
034 |
BMS communication disconnection |
|
035 |
EEPROM rear-write error |
|
036 |
DSP parameter error |
|
041 |
BMS temperature error |
|
042 |
BMS overvoltage |
|
043 |
BMS undervoltage |
|
044 |
BMS overcurrent |
|
045 |
BMS pre-charge fault |
|
046 |
BMS output short circuit |
|
050 |
Lock mark of adapter charging |
|
051 |
Lock mark of AC output |
|
052 |
Lock mark of DC output branch 1 |
|
053 |
Lock mark of DC output branch 2 |
|
054 |
Lock mark of DC output branch 3 |
|
055 |
Lock mark of DC output branch 4 |
|
Accessories:
Accessories
|
|
AC adapter (PSE authentication) |
One 500W1pc |
Vehicle charging wire |
1pc (1.5m) cigarette lighter to XT90 |
DC&MC4 wire |
|
Accessory package |
Contain all accessories, like accessory package of V6 |